Featured Equipment
SAD 9000 KIP
Access Probes Kit to perform tests of IP First Numeral according to standard IEC60529, for standards IEC 60335, 60598, ...
SAD 9000 T
Electrical Safety minilab production control and quality assurance. Up to 32 amperes multivoltage test.
SAD 9000 S
Automatic Seed Analyzer
|
|
|
Laboratory Equipment
SAD 9000 E - Tracking Test |
Automatic tracking tests for electrical appliances.
Specifications
Method for the determination of the proof and the comparative trancking indices of solid insulating materials in moist conditions.
Reference Standard
IEC 60112 - Solid electrical insulating materials.
Method for the determination of the proof and the comparative trancking indices of solid insulating materials under moist conditions.
Object
These test methods are focused in showing the relative capacity of solid insulating materials to resist tracking test voltages up to 600V, when its surface is exposed to the action of water containing ionic impurities simultaneously with electric excitement.
Definitions
Tracking: irreversible degradation of the surface of an insulating material, in form of grooves, and due to electric discharges that are initiated and developed on the surface of the material. These grooves are conductive even in dry conditions. Tracking can occur on surfaces in contact with air as in contact surfaces between different materials.
Comparative Tracking Index (CTI): Numeric value of the maximum voltage, in volts, for which the material supports the deposition of 50 drops without tracking observed.
Equipment
• Platinum-tipped electrodes
• Variable voltage up to 600 Vac
• Voltage indicator display
• Current indicator display
• Source apparent power: 0.6kVA
• Variable Resistor
• Regulates 1 A ± 0.1A current with electrodes short-circuited
• Tension in the voltmeter stabilized in 10%
• Overcurrent relay (optional not included)
• Programmable drip
• Default 1 drop every 30 seconds (± 0.5 seconds)
• Adjustable Height
• Volume of each drop between 20 and 23 mm3
Procedure
• Protection of the specimens from air drafts.
• Metal stand with adjustable height.
• Variable electrodes distance
• Frequency of dripping and drops quantity programmable.
• Drops counting on display.
|
|
|
| General Considerations |
- MANUFACTURED ACCORDING TO ISO 9001:2008 CERTIFIED QUALITY CONTROL SYSTEM.
- CALIBRATION REPORTS WITH PROPER TRACEABILITY AND UNCERTAINTY, FOLLOWING THE REQUIREMENTS OF ISO17025
- IT FULFILLS ALL TRADEMARK CERTIFICATION REQUIREMENTS AS AN EQUIPMENT FOR CONTROL THE END OF THE PRODUCTION LINE.
- INTEGRATED PATTERN SYSTEM FOR PERIODIC CHECK UP (PATTERN SET UP).
- ARGENTINEAN INDUSTRY.
- BORNED OVER 20 YEARS EXPERIENCE IN ELECTRICAL SAFETY.
- EQUIPMENTS SET UP IN ARGENTINA, CHILE, URUGUAY, CUBA AND MÉXICO.
- ALL EQUIPMENT HAVE PERIODIC VERIFICATION UNITS IN ORDER TO COMPLY WITH CERITIFICATION ORGANISM AUDITS.
|
|
|
|
|
|